pump, shower, Techflow Products Ltd, United Kingdom, manufacturers, power showers, negative head, water pumps, Standard Shower Head, Pulsating Shower Head, Champagne Shower Head, Variable Shower Head, Shower Body Jets, Shower Rainbars, Bath water boosting, House water boosting, Negative Head Systems, shower systems, shower pump systems, shower pumps, pump, shower, Techflow Products Ltd, United Kingdom, manufacturers, power showers, negative head, water pumps


M2000 Installation Instructions
QT Shower Pump: The QT120 is one of the leading shower pumps in the UK

PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE PROCEEDING WITH THE INSTALLATION. WHEN FITTING IN CONJUNCTION WITH A TECHFLOW PUMP PLEASE REFER TO THE INSTALLATION INSTRUCTIONS SUPPLIED WITH THE PUMP. IF YOU REQUIRE ANY FURTHER INFORMATION OR ASSISTANCE PLEASE CALL THE HELPLINE ON 01444 258003

TECHNICAL DATA

SPECIFICATION
MAX. INLET PRESSURE - 5 bar
  MIN.INLET PRESSURE - 0.1 bar
  MAX. PRESSURE DIFFERENTIAL  
  BETWEEN HOT AND COLD SUPPLIES - 20:1
  MAX. INLET TEMPERATURE - 65C
  INLET/OUTLET CONNECTIONS - 3/4 BSP

INSTALLATION SHOULD BE CARRIED OUT BY A COMPETENT
PERSON IN COMPLIANCE WITH THE RELEVANT WATER BY-LAWS.

A) VALVE INSTALLATION

FIG1 shows a typical installation with dedicated HOT and COLD supplies to the Maelstrom 2000 Shower Valve. Although this is not essential dedicated supplies will ensure that the flow to the Shower Valve is not affected when other appliances / outlets on the domestic water system are operated.

  1. Remove the Temperature and Flow Control Knobs from the Valve.
  2. Mark the position for the Shower Valve and Wall Outlet or Fixed Head as shown in FIG 2.
  3. Mark around the Wallplate and chase out a cavity to the correct depth as shown in FIG 3 leaving a 10mm wide (minimum) sealing face for the Wallplate.
  4. Chase out the wall as required for all inlet and outlet pipework. The outlet pipework will be different for fixed and flexible systems - see FIG 2 & 3. All pipework should be 22mm. It will be necessary to reduce the outlet pipework to 15mm immediately before the Fixed Head or Wall Outlet fittings.
  5. Fix the Valve in position in the wall cavity using the screws provided. Check that the valve inlet ports are horizontal and that the outlet ports are vertical.
  6. Flush through the inlet pipework to remove any dust/flux/solder deposits and connect to the Valve ensuring that the HOT supply is to the LEFT hand port and the COLD supply to the RIGHT hand port. Connect the outlet pipework between the Valve and Wall Outlet or Fixed Head as required. Ensure that all pipework is adequately clipped.

NOTE: The bottom Valve outlet can be used to supply bath fill / body jets etc. but a separate On/Off valve will be required (not supplied).

B) SLIDER RAIL

  1. Where required position and fix Slider Rail as shown in FIG 2.

C) COMMISSIONING

  1. Fit the Temperature and Flow Control Knobs to the Valve but not the retaining screws.
  2. Attach the Shower Hose to the Wall Outlet where fitted and lay in the bath or shower tray.
  3. Set the temperature adjustment on the Valve to full cold and turn on both hot and cold water supplies. Ensure that the Valve isolating ports are fully open by turning the adjusting screw anti-clockwise. Open the flow control and allow water to run for several minutes until all air is purged from the system.
  4. Move the temperature control to full hot and repeat (iii) above.

CHECK FOR LEAKS.

D) COMPLETE INSTALLATION

  1. Remove Temperature and Flow Control Knobs and tile to complete.
  2. Apply a bead of sealant to the groove in the Wallplate and fit over Valve collars. A film of washing up liquid applied to the bore of the grommets will simplify installation. Push Wallplate fully home a clean off any excess sealant.
  3. Re-fit control knobs and retaining screws. Fit screw blanking caps.
  4. Where appropriate fit Wall Outlet or Fixed Head wallplate.

E) OPERATING INSTRUCTIONS

  1. The upper control knob is Flow Control and rotating anticlockwise will turn on the shower.
  2. The lower control knob is Temperature Control and rotating clockwise reduces the set temperature, rotating anti-clockwise increases temperature.
  3. When rotating the Temperature Control knob anti-clockwise a pre-set stop position is reached. This position is factory set at 38c, the normal showering temperature. However, if higher temperatures are required the stop can be overridden by depressing the red button and continuing to rotate the control knob anti-clockwise. If required the Valve can be re-calibrated and the stop temperature adjusted. (See section G)

F) CLEANING

Wipe over with a soft damp cloth to remove stains.

ABRASIVE CLEANERS OR STRONG DETERGENTS
WILL DAMAGE THE SURFACE FINISH

G) CALIBRATION / STOP POSITION ADJUSTMENT

  1. Carefully remove the screw blanking cap and the retaining screw from the Temperature Control Knob.
  2. Adjust the Temperature Control until the required temperature is achieved.
  3. Without turning the knob remove and re-fit with the Control Knob set at the stop position.
  4. Re-fit screw and blanking cap.

H) THERMOSTATIC CARTRIDGE / FILTER REMOVAL (See Fig 4)

  1. Carefully remove Wallplate.
  2. Close both hot and cold isolating valves by rotating screws clockwise.
  3. Remove the blanking cap and screw from the Temperature Control Knob and remove knob.
  4. Unscrew valve Collar from cartridge.
  5. Using a 19mm spanner remove thermostatic cartridge.
  6. Wash off any deposits from filter and remove lime-scale deposits by washing in vinegar.
  7. Lubricate O ring seals with silicone grease and re-assemble in reverse order.

WARRANTY
The TERMS and CONDITIONS of the WARRANTY are:

1.The Scope of the Warranty

TECHFLOW PRODUCTS LTD. (‘The Company’ ) will, subject to the terms and conditions below and for the warranty period specified in paragraph 3, repair or replace free of charge any of its products that, in the opinion of the company, are defective because of faulty materials or workmanship. This warranty will not apply to any of the Company’s product (s) that in the opinion of the company have been modified altered or misused in any way or where the products have been incorrectly installed or operated other than as described in the Company’s Installation Instructions, or if any servicing or repair of the product (s) has been carried out by anyone other than our authorised Company Service Engineer or Dealer.

2. TERMS AND CONDITIONS
This warranty is available to you on the following terms and conditions.

2.1 You are the original purchaser of the product(s) from an authorised dealer of the company (‘The Dealer’) and not an assignee or subsequent purchaser of the product .

2.2 You must evidence the date of purchase of the product(s) by retaining the original invoice or receipt from the Dealer. Without such evidence the to Company reserves the right to reject any claim under the terms of the warranty.

2.3 Any alleged defect of the Company’s product(s) giving rise to liability as stated in paragraph 1 must be advised to the Company within 30 days of discovery

3. WARRANTY PERIOD

3.1 This warranty will run for a period of 3 years from the date of purchase.

3.2 The warranty period in respect of any product(s) repaired or replaced under the terms of the warranty shall be that part of the above 3 year period which remains un-expired.

4. In the event of a claim for repairs or replacement being made under the terms of the warranty where, in the opinion of the Company , the defect has not been caused by the Companies materials or workmanship then the company reserves the right to charge the claimant at the hourly rates and list prices prevailing in respect of any service engineer’s time and any replacement parts.

5. This warranty is given in addition to and does not alter your statutory rights.

6. This warranty is applicable only to products(s) purchased and used exclusively in the U.K. and Eire only

7. Where the company makes a replacement the product(s) replaced shall be returned to the company immediately and shall become the property of the company

8. No authority has been given to any person, company or any other party to waive the terms of this warranty.

FIG 1
TYPICAL MAELSTROM 2000
INSTALLATION

Fig 1 - Typical Maelstrom 2000 Installation


FIG 2
APPROX. MOUNTING POSITIONS FOR FIXED
AND FLEXIBLE SYSTEMS

FIG 2 - APPROX. MOUNTING POSITIONS FOR FIXED AND FLEXIBLE SYSTEMS
** APPLIES TO GRAVITY SYSTEMS ONLY. THIS DISTANCE
CAN BE REDUCED TO 400MM FOR PUMPED SYSTEMS.


FIG 3 - VALVE INSTALLATION
DIAGRAM

FIG 3 - VALVE INSTALLATION DIAGRAM